| Quick Links |
|
|
| Delta Group Links |
|
| |
| Delta News |
|
|
| E-News Letter |
|
|
|
|
|
| |
|
| |
| Small power system |
This power system range is from 300 W to 8000W, which is a perfect solution for digital subscriber line (DSL), Fiber in the loop, transmission, PBX, network components in the telecommunication networks and data networks. |
| |
|
Features
- A.C. Single phase
- Complete Power plant in one Shelf Including Rectifier and Alarm Unit
- Hot Swappable 300Watt rectifiers
- All Modules are front accessible
- High power density in N+1 configuration
- System dimension is (H x W x D)40.5x450x231.9mm
- Battery Disconnect Breaker
- Low Voltage Disconnect ( Battery deep discharge protection)
- Temperature Compensation Voltage Control
- Equalize Charge Timer
- Wide operating temperature range
- Remote monitoring and control
Basic Specifications
- AC Input: 90~275 Vac(Single Phase)
- System Max. Capacity:
- 48V/7A~14A - Operating Temp.: 20' C ~ +75' C
|
 |
| |
|
| |
| |
|
Features
- A.C. Single phase
- Complete Power plant in one Shelf Including Rectifier, Battery Disconnect and Alarm Unit
- Hot Swappable 600Watt rectifiers
- All Modules are front accessible
- High power density in N+1 configuration
- System dimension is (H x W x D)133x305x482.5 mm
- A.C. voltage monitoring and cutoff in unbalance Condition
- Battery Disconnect Breaker
- Low Voltage Disconnect( Battery deep discharge protection)
- Temperature Compensation Voltage Control
- Equalize Charge Timer
- Wide operating temperature range
- Remote monitoring and control
Basic Specifications
- AC Input: 90~275 Vac(Single Phase)
- System Max. Capacity:
- 48V/10A~50A - Operating Temp.:
20' C ~ +65' C
- DC Distribution(Customized) Load distribution (With Critical & non critical load configuration) Battery distribution (Fuse/ Breaker)
- UL/CUL Approve
|
 |
| |
|
| |
| |
|
Features
- A.C. Single phase/ Three phase supply
- Complete Power plant in 19” mountable cabinet Including Rectifier, Battery Disconnect and Alarm Unit
- Hot Swappable 2000 Watt rectifiers
- All Modules are front accessible
- High power density in N+1 configuration
- System dimension is (H x W x D)310x450x700 mm
- A.C. voltage monitoring and cutoff in unbalance Condition
- Class-C level surge protection
- Battery Disconnect Breaker
- Low Voltage Disconnect( Battery deep discharge protection)
- Temperature Compensation Voltage Control
- Equalize Charge Timer
- Wide operating temperature range
- Remote monitoring and control
Basic Specifications
- AC Input: 90~275 Vac(Single Phase)
- System Max. Capacity: -48V/42A~168A - Operating Temp.: -20' C ~ +70' C
- AC Distribution
Mains MCB double pole
Separate breaker for each Module
- DC Distribution(Customized)
Load distribution (With Critical & non critical load configuration)
Battery distribution (Fuse/ Breaker)
|
 |
| |
|
| |
 |
| |
|
|
| |
|
| |
|
|
|
|
|
|
| |
|
|