Quick Links

 

Home
  About Delta
  Corporate Culture
  Products
  Support and Services
  Quality Accreditation
  Contact Us
   
      Delta Group Links
icon_blank icon_blank
icon_arrow Delta Group
icon_arrow Delta Electronics, Inc.
icon_blank icon_blank
icon_arrow Delta Networks, Inc.
icon_blank icon_blank
icon_arrow Cyntec Co., Ltd.
icon_blank icon_blank
icon_arrow DelSolar Co., Ltd.
icon_blank icon_blank
icon_arrow Delta Electronics  (Thailand)Public  Company Ltd.
icon_blank icon_blank
icon_arrow Delta Energy Systems
icon_blank icon_blank
icon_arrow Delta-CIMIC Electronics  Co., Ltd.
icon_blank icon_blank
icon_arrow Delta Electronics  Foundation
icon_blank icon_blank
icon_arrow Delta Electronics Europe
icon_blank icon_blank
icon_arrow Delta Electronics  (Japan), inc.
 
Delta News
E-News Letter



 
 
Small power system

This power system range is from 300 W to 8000W, which is a perfect solution for digital subscriber line (DSL), Fiber in the loop, transmission, PBX, network components in the telecommunication networks and data networks.
 

 

Features

  • A.C. Single phase
  •  Complete Power plant in one Shelf Including Rectifier and   Alarm Unit
  • Hot Swappable 300Watt rectifiers
  • All Modules are front accessible
  • High power density in N+1 configuration
  • System dimension is (H x W x D)40.5x450x231.9mm
  • Battery Disconnect Breaker
  • Low Voltage Disconnect ( Battery deep discharge protection)
  • Temperature Compensation Voltage Control
  • Equalize Charge Timer
  • Wide operating temperature range
  • Remote monitoring and control

Basic Specifications

  • AC Input: 90~275 Vac(Single Phase)
  • System Max. Capacity:
  • 48V/7A~14A - Operating Temp.: 20' C ~ +75' C
 
 
 

 

Features

  • A.C. Single phase
  • Complete Power plant in one Shelf Including Rectifier, Battery Disconnect and Alarm Unit
  • Hot Swappable 600Watt rectifiers
  • All Modules are front accessible
  • High power density in N+1 configuration
  • System dimension is (H x W x D)133x305x482.5 mm
  • A.C. voltage monitoring and cutoff in unbalance Condition
  • Battery Disconnect Breaker
  • Low Voltage Disconnect( Battery deep discharge protection)
  • Temperature Compensation Voltage Control
  • Equalize Charge Timer
  • Wide operating temperature range
  • Remote monitoring and control

Basic Specifications

  • AC Input: 90~275 Vac(Single Phase)
  • System Max. Capacity:
  • 48V/10A~50A - Operating Temp.: 20' C ~ +65' C
  • DC Distribution(Customized) Load distribution (With Critical & non critical load configuration) Battery distribution (Fuse/ Breaker)
  • UL/CUL Approve
 
 
 

 

Features

  • A.C. Single phase/ Three phase supply
  • Complete Power plant in 19” mountable cabinet Including Rectifier, Battery Disconnect and Alarm Unit
  • Hot Swappable 2000 Watt rectifiers
  • All Modules are front accessible
  • High power density in N+1 configuration
  • System dimension is (H x W x D)310x450x700 mm
  • A.C. voltage monitoring and cutoff in unbalance Condition
  • Class-C level surge protection
  • Battery Disconnect Breaker
  • Low Voltage Disconnect( Battery deep discharge protection)
  • Temperature Compensation Voltage Control
  • Equalize Charge Timer
  • Wide operating temperature range
  • Remote monitoring and control

Basic Specifications

  • AC Input: 90~275 Vac(Single Phase)
  • System Max. Capacity: -48V/42A~168A - Operating Temp.: -20' C ~ +70' C
  • AC Distribution
    Mains MCB double pole
    Separate breaker for each Module
  • DC Distribution(Customized)
    Load distribution (With Critical & non critical load configuration)
    Battery distribution (Fuse/ Breaker)
 
 
 
 
 
 
 
   
 
Copyright © Delta Electronics, Inc. 2008, All Rights Reserved.